1 Wine Cellar Cooling Systems Through-the-Wall Wine Cellar Cooling Systems Installation, Operation and
10 Accessories and Optional Equipment Installation Sleeve Each Wine Guardian system includes an EasyMount™ installation sleeve to be used
11 Overview of the Wine Guardian Unit Refer to illustrations on page 10 Cabinet – The cabinet is constructed of aluminum with a powder coate
12 Overview Heronhill - for all your Wine Guardian requirementsTel: 01823 665660www.heronhill.co.ukFax: 01823 665807
13 Safety The following is suggested before installing or maintaining the Wine Guardian System: 1) Read these instructions 2) Keep these instructions
14 Following is a typical example of a CAUTION message as it could appear in the manual: CAUTION RISK OF PERSONAL INJURY OR DAMAGE TO EQUIPMENT Im
15 Hot Parts Hazards Electric Resistance heating elements (if equipped) must be disconnected prior to servicing. Electric heaters may s
16 CAUTION Do not block any supply or return air opening. Install in accordance with the instructions in the Wine Guardian manual. Protect the
17 Installation CAUTION SHARP EDGES RISK OF SERIOUS INJURY Sharp edges are present inside the Wine Guardian system. Pre-installatio
18 WARNING RISK OF PERSONAL INJURY OR DAMAGE TO EQUIPMENT Modification to the equipment may cause inj
19 Where to locate the unit? It can be mounted flush with the racking or flush with the wall on the wine cellar side. How to mount the unit? A m
2 TABLE OF CONTENTS Directory of Terms ... 4 Introduction ...
20 You must then move the red voltage switch in the opposite direction as from the factory to move the internal power from the condenser side to the
21 Step 3 Slide the EasyMount™ sleeve through the wall penetration so that the flanged area of the sleeve sits flush with the surface of the wall. E
22 Installing the Condensate Overflow Condensate generation is a natural by-product of air conditioning systems. The Wine Guardian cooling coils are
23 Wiring the System for Power WARNING ELECTRICAL SHOCK HAZARD The electrical outlet and wiring installation must meet the national and local buildi
24 Installing the Thermostat and Communication Cable The Wine Guardian Local Interface Controller is a combination temperature and humidity control
25 2. Remove the back plate of the controller and mark the mounting points at the desired location. (F
26 Installation of the Optional Wine Guardian Remote Sensor The Remote Sensor is a combination temperature and humidity sensor only. It is designe
27 4. Drill two .32cm holes and insert anchors (provided) within the mounting surface. Anchors may not be requir
28 Joining Communication Cable Changing Jumper Positions (Averaging readings from Remote Sensor) If using multi
29 Standard Controller Functions How to: Turn system on/off Press the On/Off” button once. NOTE: There is a five- second t
3 Wiring the System for Power ... 23 Electrical Plug Configuration ..
30 Deg F or Deg C Setting 1 Press the “Down” arrow to change temperature from Deg F to Deg C. Press the “Up” arrow to change temperatur
31 Advanced Settings- Special access required. Contact Wine Guardian Service Department for access code Setting 8 Press “Mode” button to advanc
32 Differential temperature adjustment Setting 16 Press “Mode” button to advance to Setting 16. Press the “Up” or “Down” buttons to adjust
33 Alarm Codes High temperature alarm Press the “Up” or “Down” arrow once to change screen from alarm to normal Temperature and Humidity indicatio
34 Starting-up and Operating the Wine Guardian Control Settings The control has been wired and set up in the factory for testing with default setti
35 Regulating the Wine Cellar Temperature To keep the entire wine cellar at the same temperature, set the thermostat to run the supply fan continuous
36 CAUTION EXPOSURE TO MICROBIAL GROWTH (MOLD) CAN CAUSE SERIOUS HEALTH PROBLEMS Standing water in drain pans promote microbial growth (mold) that c
37 High Pressure Switch has Shut the System Down Every Wine Guardian system has a manual reset high pressure switch in the refrigeration system. This
38 Troubleshooting WARNING BEFORE PROCEEDING, READ AND UNDERSTAND THE SAFETY INFORMATION CONTAINED IN THE SAFETY SECTION OF THE WINE GUARDIAN MANUA
39 Unit is Operating and Blows Evaporator Air, but the Supply Air is not Colder than the Return Air from the Cellar Possible Cause Solution Thermost
4 Directory of Terms Ambient Air – The surrounding area outside the cellar such as a room, basement, garage or outdoors. CACLS – Cubic feet per secon
40 Problems Controlling Cellar Humidity Humidity too low or supply air is too cold, without optional Standalone humidifier Possible Cause Solution
41 Humidity too high when unit is not running Possible Cause Solution System needs to run to dehumidify Lower room temperature setpoint. Seal openi
5 Introduction Dear Customer, Congratulations and thank you for purchasing a Wine Guardian cooling system. We believe it to be the best wine cellar
6 Review the Packing Slip to Verify: Model number Factory-installed options System accessories If any items listed on the packing slip do n
7 CAUTION THE AIR EXHAUST FORM THE CONDENSER FAN IS WARM AND CAN BE 20 DEGREES F ABOVE THE ENTERING AIR TEMPERATURE. Wine Guardian Controls
8 Wine Guardian Controls Main Control: Performs all switching functions and interfaces with inputs and output
9 Standard Specifications The Wine Guardian System Contains A capillary tube expansion to control the flow of refrigeration into the evaporato